Ni (II) - Selective Potentiometric Sensor Based on New Schiff base ligand, S-octyl-3-(furan-2-ylmethylene) dithiocarbazate
DOI:
https://doi.org/10.32628/IJSRST2613174Keywords:
Nickel-selective sensor, PVC matrix, Schiff base, PotentiometryAbstract
The construction and performance of a polymeric membrane electrode made with a new Schiff base called S-octyl-3-(furan-2-ylmethylidene) dithiocarbazate [L] for measuring nickel ions is described. The study revealed that the electrode performance is strongly influenced by the composition of the membrane matrix. The best results were achieved with a membrane made of (L) (2.5%): PVC (32.6%): DOP (62.4%): NaTPB (2.5%). This electrode gives a Nernstian response for nickel ions in concentrations between 4.2×10-8 and 1.0×10-1 M, with a detection limit of 2.1×10-9. It works well across a wide pH range from 2.5 to 10 and responds quickly, in about 9 seconds. The electrode also works in partially non-aqueous solutions containing up to 30% (v/v) methanol, ethanol, or acetonitrile and can be used for up to 3.0 months. It has excellent selectivity for Ni(II) over other mono-, bi- and trivalent cations. Its usefulness for analysis was tested by using it to measure nickel in various samples. The sensor's practical use was shown by using it as an indicator electrode in potentiometric titrations of Ni²+ against EDTA.
Downloads
References
Greenwood, N. N., & Earnshaw, A. (1997). Chemistry of the Elements (2nd ed.). Butterworth-Heinemann.
Cotton, F. A., Wilkinson, G., Murillo, C. A., & Bochmann, M. (1999). Advanced Inorganic Chemistry (6th ed.). Wiley.
Davis, J. R. (Ed.). (2000). Nickel, Cobalt, and Their Alloys. ASM International.
Reed, R. C. (2006). The Superalloys: Fundamentals and Applications. Cambridge University Press.
Winter, M., & Brodd, R. J. (2004). What are batteries, fuel cells, and supercapacitors? Chemical Reviews, 104(10), 4245–4269.
Manthiram, A. (2017). An outlook on lithium ion battery technology. ACS Central Science, 3(10), 1063–1069.
Crundwell, F. K., et al. (2011). Extractive Metallurgy of Nickel, Cobalt and Platinum Group Metals. Elsevier.
Das, K. K., Das, S. N., & Dhundasi, S. A. (2008). Nickel, its adverse health effects & oxidative stress. Indian Journal of Medical Research, 128(4), 412–425.
Fries, J., Getrost, H., & Merck, D. E. (1977). Organic reagents trace analysis. E. Merck.
Haase, O., Klare, M., Broekaert, J. A., & Krengel-Rothensee, K. (1998). Evaluation of the determination of mercury at the trace and ultra-trace levels in the presence of high concentrations of NaCl by flow injection–cold vapour atomic absorption spectrometry using SnCl 2 and NaBH 4 as reductands. Analyst, 123(6), 1219-1222.
MagalhŃes, C. C., Krug, F., & Fostier, A. (1997). Direct determimnation of mercury in sediments by atomic absorption spectrometry. Journal of Analytical Atomic Spectrometry, 12(10), 1231-1234.
Potts, L. W., (1987). Quantitative analysis: theory and practice, Longman Higher Education.
De Torres, A. G., Pavón, J. M. C., & Castellon, E. R. (1998). Automated on-line separation–preconcentration system for inductively coupled plasma atomic emission spectrometry and its application to mercury determination. Journal of Analytical Atomic Spectrometry, 13(4), 243-248.
Hassan, S. S., & Mahmoud, W. H. (1995). PVC matrix membrane electrodes based on cobalt and nickel phenanthroline complexes for selective determination of cobalt (II) and nickel (II) ions. Microchimica Acta, 117(3), 121-128.
Pleniceanu, M., Preda, M., Muresan, N., & Simoiu, L. (1996). New liquid-membrane electrodes used for the determination of copper and nickel. Analytical letters, 29(9), 1485-1496.
Gupta, V. K., Jain, A. K., Singh, L. P., & Khurana, U. (1997). Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel (II). Analytica Chimica Acta, 355(1), 33-41.
Ganjali, M. R., Hosseini, S. M., Javanbakht, M., & Hashemi, O. R. (2000). Nickel (II) Ion-Selective Electrode Based on 2, 5-Thiophenyl bis (5-tert-Butyl-1, 3-Benzoxazole. Analytical letters, 33(15), 3139-3152.
Gupta, V. K., Prasad, R., Kumar, P., & Mangla, R. (2000). New nickel (II) selective potentiometric sensor based on 5, 7, 12, 14-tetramethyldibenzotetraazaannulene in a poly (vinyl chloride) matrix. Analytica Chimica Acta, 420(1), 19-27.
Shamsipur, M., Kazme, S.Y. (2000). A- pvc based dibenzodiaza – 15 crown -4- membrane Potentiometric sensor for Ni(II). Electroanalysis,18(12), 1472 – 1475.
Mousavi, M. F., Alizadeh, N., Shamsipur, M., & Zohari, N. (2000). A new PVC-based 1, 10-dibenzyl-1, 10-diaza-18-crown-6 selective electrode for detecting nickel (II) ion. Sensors and Actuators B: Chemical, 66(1-3), 98-100.
Singh, A. K., Sharma, C. L., Baniwal, S., & Panwar, A. (2001). Nickel (II)‐Selective Membrane Electrode Based on Macrocyclic Ligand. Electroanalysis: An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis, 13(14), 1209-1214.
Gupta, V. K., Prasad, R., & Kumar, A. (2002). Dibenzocyclamnickel (II) as ionophore in PVC-matrix for Ni2+-selective sensor. Sensors, 2(10), 384-396.
Mashhadizadeh, M. H., & Momeni, A. (2003). Nickel (II) selective membrane potentiometric sensor using a recently synthesized mercapto compound as neutral carrier. Talanta, 59(1), 47-53.
Mashhadizadeh, M. H., Sheikhshoaie, I., & Saeid-Nia, S. (2003). Nickel (II)-selective membrane potentiometric sensor using a recently synthesized Schiff base as neutral carrier. Sensors and Actuators B: Chemical, 94(3), 241-246.
Belhamel, K., Ludwig, R., & Benamor, M. (2005). Nickel ion-selective PVC membrane electrode based on a new t-octyl-calix [6] arene derivative. Microchimica Acta, 149(1), 145-150.
Jain, A. K., Gupta, V. K., Ganeshpure, P. A., & Raisoni, J. R. (2005). Ni (II)-selective ion sensors of salen type Schiff base chelates. Analytica chimica acta, 553(1-2), 177-184.
Yari, A., Azizi, S., & Kakanejadifard, A. (2006). An electrochemical Ni (II)-selective sensor-based on a newly synthesized dioxime derivative as a neutral ionophore. Sensors and Actuators B: Chemical, 119(1), 167-173.
Kumar, K. G., Poduval, R., Augustine, P., John, S., & Saraswathyamma, B. (2006). A PVC plasticized sensor for Ni (II) ion based on a simple ethylenediamine derivative. Analytical sciences, 22(10), 1333-1337.
Gupta, V. K., Goyal, R. N., Agarwal, S., Kumar, P., & Bachheti, N. (2007). Nickel (II)-selective sensor based on dibenzo-18-crown-6 in PVC matrix. Talanta, 71(2), 795-800.
Girish Kumar, K., Poduval, R., John, S., & Augustine, P. (2006). A PVC plasticized membrane sensor for nickel ions. Microchimica Acta, 156(3), 283-287.
Gupta, V. K., Jain, A. K., Ishtaiwi, Z., Lang, H., & Maheshwari, G. (2007). Ni2+ selective sensors based on meso-tetrakis-{4-[tris-(4-allyl dimethylsilyl-phenyl)-silyl]-phenyl} porphyrin and (sal) 2trien in poly (vinyl chloride) matrix. Talanta, 73(5), 803-811.
Zamani, H. A., Masrournia, M., Rostame-Faroge, M., Ganjali, M. R., & Behmadi, H. (2008). Construction of nickel (II) PVC membrane electrochemical sensor based on 5-methoxy-5, 6-Diphenyl-4, 5 Dihydro-3 (2H)-pyridazinethione as a novel ionophore. Sensor Letters, 6(5), 759-764.
Gupta, V. K., Singh, A. K., & Pal, M. K. (2008). Ni (II) selective sensors based on Schiff bases membranes in poly (vinyl chloride). Analytica chimica acta, 624(2), 223-231.
Singh, A. K., Singh, P., & Mehtab, S. (2009). Polymeric membrane and coated graphite electrode based on newly synthesized tetraazamacrocyclic ligand for trace level determination of nickel ion in fruit juices and wine samples. Journal of Inclusion Phenomena and Macrocyclic Chemistry, 63(1), 87-95.
Rezaei, B., Hadadzadeh, H., & Azimi, A. (2011). Nickel (II) Selective PVC‐Based Membrane Sensor Using a Schiff Base. International Journal of Spectroscopy, 2011(1), 7463 -72.
Elsaid, F. A., Hamza, S., Rizk, N., Matter, H. A., & Amerah, E. A. (2013). Ni2+ selective membrane sensors based on sulfamethoxazole diazonium resorcinol in poly (vinyl chloride) (PVC) matrix. Arabian Journal for Science and Engineering, 38(7), 1681-1689.
Tomar, P. K., Chandra, S., Malik, A., & Kumar, A. (2013). Nickel analysis in real samples by Ni2+ selective PVC membrane electrode based on a new Schiff base. Materials Science and Engineering: C, 33(8), 4978-4984.
Subashini, G., Shankar, R., Arasakumar, T., & Mohan, P. S. (2017). Quinoline appended pyrazoline based Ni sensor and its application towards live cell imaging and environmental monitoring. Sensors and Actuators B: Chemical, 243, 549-556.
Isildak, O. (2017). Nickel (II)-selective PVC membrane potentiometric electrode using 1, 4, 8, 12-tetraazacyclopentadecane as ionophore. Der Pharma Chem, 9, 64-67.
Kaur, H., Chhibber, M., & Mittal, S. K. (2017). Acyclic arylamine-based ionophores as potentiometric sensors for Zn2+ and Ni2+ ions. C, 3(4), 34.
Mi, Y., & Bakker, E. (1999). Determination of complex formation constants of lipophilic neutral ionophores in solvent polymeric membranes with segmented sandwich membranes. Analytical chemistry, 71(23), 5279-5287.
Khan, S. S., Rakib, M. A., Shek, M. M., Howlader, M. B. H., Karim, M. R., Ansary, M. R. H., & Rahman, S. (2025). A Novel Nickel (II) Complex Featuring Furan‐Based Dithiocarbazate Schiff Base: Synthesis, Crystal Structure, DFT Insights, Optical Properties, and Molecular Docking Against Cyclooxygenase‐2 Enzyme. ChemistrySelect, 10(37), e04174.
Craggs, A., Moody, G. J., & Thomas, J. D. R. (1974). PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments. Journal of Chemical Education, 51(8), 541.
Katsu, T., Ido, K., Takaishi, K., & Yokosu, H. (2002). Thallium (I)-selective membrane electrodes based on calix [6] arene or calix [5] arene derivatives. Sensors and Actuators B: Chemical, 87(2), 331-335.
Gadzekpo, V. P. Y., & Christian, G. D. (1984). Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method. Analytica Chimica Acta, 164, 279-282.
Lrving, H. M. N. H., Zettler, H., Baudin, G., Freiser, H., Guilbault, G. G., Menis, O., ... & Fischer, W. (1976). Recommendations for nomenclature of ion-selective electrodes (recommendations 1975). Pure Appl. Chem, 48, 127-132.
Lrving, H. M. N. H., Zettler, H., Baudin, G., Freiser, H., Guilbault, G. G., Menis, O., ... & Fischer, W. (1976). Recommendations for nomenclature of ion-selective electrodes (recommendations 1975). Pure Appl. Chem, 48, 127-132.
Bakker, E., Xu, A., & Pretsch, E. (1994). Optimum composition of neutral carrier-based pH electrodes. Analytica chimica acta, 295(3), 253-262.
Morf, W. E. (2012). The principles of ion-selective electrodes and of membrane transport (Vol. 2). Elsevier.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 International Journal of Scientific Research in Science and Technology

This work is licensed under a Creative Commons Attribution 4.0 International License.
https://creativecommons.org/licenses/by/4.0